Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Operations and Installation Guide DOC. 8163E Thermostats: CHV-TSTAT and CHV-THSTAT
3
Heating and Cooling Systems
The CHV-TSTAT and CHV-THSTAT can control the following heating and cooling
systems:
1-stage heat
1-stage heat, 1stage cool
1-stage heat, 1-stage cool (heat pump with auxiliary heat)
2-stage heat
2-stage heat, 1-stage cool
1-stage heat, 2-stage cool
2-stage heat, 2-stage cool
2-stage heat, 2-stage cool (heat pump with auxiliary heat)
Wide range cool option suitable for wine cellars or other chilling processes*
Slab settings for heating and floor warming systems*
NOTE: 2-stage heating Unlike traditional furnaces that turn on and run at full
capacity with each demand for heating, 2-stage heat operates like two separate
furnaces to maintain more consistent comfort in the home. The unit starts out
running in its first stage, and operates at a fraction of its heating capacity. This
reduced capacity is sufficient to warm the home on mild winter days. But when the
temperature outside goes very low, the furnace adjusts to full capacity (second stage)
to meet the demand for heat within the home.
2-stage cooling In warm weather, the first stage of the cooling equipment operates
at a fraction of the total cooling capacity. On very hot days, the second stage of the
cooling equipment energizes, and the cooling system operates at full capacity.
*Firmware version 2.0 or higher.