Crestron e-control Database Manager SW-DBM
73 Appendices Installation & Reference Guide — DOC. 5823
ErrTrigger system signal; scroller signal
Description Trigger for ErrNumber and ErrString
Direction
Server to System
Type
Digital
Value
Pulse
Expected Reply
None
Comments This signal is sent after the ErrNumber and ErrString to indicate that an error
condition has occurred.
For an e-mail scroller, this and the other Err signals are always defined. For a
standard scroller, they are optionally defined in the Standard Scroller Definition
window (Local Errors checkbox). When not defined, the server attempts to use the
SYSTEM error signals, unless they too are not defined.
This signal can be safely ignored.
This signal cannot be defined in an emailer scroller.
See Also ErrNumber, ErrString signals