Crestron e-control Database Manager SW-DBM
61 •• Appendices Installation & Reference Guide — DOC. 5823
ClearRec scroller signal
Description
Causes the server to nullify every field in the opened record.
Direction
System to Server
Type
Digital
Value
Pulse
Expected Reply Possible Data signals (all with null strings); followed by pulse of Done signal
Comments
This signal is only effective when a record is opened. This would normally be the
most recent record “picked.” If no record has yet been picked since the query was
initiated (or the scroller has been scrolled, or the CloseRec signal has been
pulsed), pulsing ClearRec produces the following error:
You must choose a record first.
If successful, the data fields are all blanked. As usual, fields already blanked are
not signaled (see “String Proxies,” page 54).
This signal cannot be defined in an emailer scroller.
Not implemented in the present release.
See Also Data, CloseRec