As of the date of manufacture, the C2N-SDC has been tested and found to comply with
specifications for CE marking.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Crestron Electronics, Inc. Operations & Installation Guide - DOC. 6316A
15 Volvo Drive Rockleigh, NJ 07647 (2011633)
Tel: 888.CRESTRON 11.14
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
Further Inquiries
To locate specific information or resolve questions after reviewing this guide, contact Crestron's True Blue Support at
1-888-CRESTRON [1-888-273-7876] or, for assistance within a particular geographic region, refer to the listing of
Crestron worldwide offices at www.crestron.com/offices.
To post a question about Crestron products, log onto Crestron’s Online Help at www.crestron.com/onlinehelp.
First-time users must establish a user account to fully benefit from all available features.
Future Updates
As Crestron improves functions, adds new features, and extends the capabilities of the C2N-SDC, additional
information may be made available as manual updates. These updates are solely electronic and serve as
intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as
an “Addendum” in the Download column.
WARNING: To avoid fire, shock, or death, turn off power at circuit breaker or fuse and test that power is off before
wiring!
NOTES: Observe the following points.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
This product should be installed by a qualified electrician.
PREPARING AND CONNECTING WIRES
Strip the ends of the wires approximately 1/4 in (6 mm). Use care to avoid nicking the conductors. Twist together
the ends of the wires that share a connection. Apply solder only to the ends of the twisted wires. Avoid tinning too
far up the wires or the end becomes brittle.
Crestron C2N-SDC
Shade and Drape Controller, 120 Vac
Operations & Installation Guide
DESCRIPTION
The Crestron
®
C2N-SDC is a 2-channel shade and drape controller designed to provide a
convenient and cost-effective solution for controlling a variety of motorized window
treatments as well as motorized doors, sunroofs, lifts, and projection screens. The
C2N-SDC is a Cresnet
®
device with two independently controlled 120 Vac outputs. Each
output provides up and down or open and close control of a conventional three-wire
bidirectional motor. Built-in timing and interlock logic make it easy to program the C2N-SDC
for failsafe operation.
INSTALLATION
NOTE: Before using the C2N-SDC, ensure the device is using the latest firmware. Check
for the latest firmware for the C2N-SDC at www.crestron.com/firmware. Firmware is
loaded onto the device using Crestron Toolbox™.
The C2N-SDC can be mounted in a 2-gang electrical box or a 4 inch square (1900)
electrical box. The electrical box must be at least 1 1/2 inches (39 mm).
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed
including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
Do not use outdoors.
Do not mount near gas or electric heaters.
Equipment should be mounted in locations and at heights where it will not be
subjected to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer may cause
an unsafe condition.
Do not use this equipment for other than its intended use.
All servicing should be performed by qualified service personnel.
If any Emergency Circuits are fed or controlled from this panel, it must be located
electrically where fed from a UPS, generator, or other guaranteed source of power
during emergency and power outage situations.
SAVE THESE INSTRUCTIONS.
Mounting to a 2-Gang Box
When mounting in a 2-gang electrical box, use the four #06-32 3/8 inch pan head screws,
two #6 washers, and two 1/4 inch ID nylon cable clamps. Mount the 2-gang electrical box
horizontally (with the mounting tabs on the left and right sides of the box) to maintain an
upright orientation of the C2N-SDC. Refer to the following illustration (wiring is not shown
for clarity).
Mounting to a 4 Inch Square (1900) Box
When mounting the C2N-SDC in a 4 inch square electrical box, use the two 8-32 3/8 inch
pan head screws, two #8 flat washers, and the two 1/4 inch ID nylon cable clamps as
shown in the following illustration (wiring is not shown for clarity).
(2) 1/4 in ID Nylon Cable Clamps
(2) 8-32 3/8 in Pan Head
Screws
(2) #8 Flat Washers
4 in Square (1900) Electrical Box
2-Gang Electrical Box
(4) 06-32 3/8 in
Pan Head Screws
(2) #6 Flat
Washers
(2) 1/4 in ID Nylon
Cable Clamps