Crestron CNXLIR Specifiche Pagina 11

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 10
Crestron CNXLIR Infrared Learner
CNXLIR Troubleshooting (continued)
TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION
CNXLIR is trying to
receive stray signals
(external noise such as
sunlight, etc.).
Make sure the receiving window is
positioned to avoid interference
from direct sunlight and high
frequency fluorescent light.
RDY LED or
SGNL LED
does not
illuminate or
goes out
immediately
in Learn
mode.
Applying signal before
CNXLIR is ready.
Wait for RDY LED before sending
a signal to learn.
OVRDR
LED
illuminates.
IR signal from remote is
too strong.
Increase the distance between the
IR source and the CNXLIR.
Computer connection
cable is wrong type.
Make sure the connection cable is
a RS-232, DB-9 “straight through”
cable with hardware handshaking
capability. Cable must include
RTS and CTS connections.
DEAL for
Windows
does not
communicat
e with the
CNXLIR.
Incorrect COM port.
Select the correct COM port
setting using the Preferences
window (Hardware Settings tab) of
the DEAL for Windows software.
Test
equipment
does not
respond to
IR signals
delivered by
CNXLIR.
Test signal is not being
received.
1. Reposition IR emitter and test
again.
2. Relearn and verify signal.
3. Test again.
Make sure the IR remote is held
steady on a firm surface while
transmitting IR codes to the
CNXLIR.
Tap the button on the IR remote
instead of holding the button when
transmitting to the CNXLIR.
If the frequency of the learned IR
remote is 455 kHz or more, check
that the sample rate in the DEAL for
Windows is not set to Low Sample
Rate (Edit | Preferences). If DEAL
for Windows is set to sample at the
low rate, set it to Medium Sample
Rate and relearn.
IR signal learned
incorrectly.
In DEAL for Windows, disable
“Signal Optimization” (Edit |
Preferences).
Test
equipment
does not
respond to
IR signals
delivered
from
CNXLIR.
Weak batteries
IR remote batteries may be weak.
Replace batteries in IR remote and
relearn.
IR code
does not
verify.
IR device could be a
“multi-code” remote.
Refer to the DEAL for Windows
help file that is included with DEAL
for Windows.
(continued on following page)
Operations Guide - DOC. 8131B Infrared Learner: CNXLIR 7
Vedere la pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16

Commenti su questo manuale

Nessun commento